FT Series Turbine Flowmeters Description Flow Technology’s FT Series turbine flowmeters utilize a proven flow measurement technology to provide exceptionally reliable digital outputs. Because of their versatility, these flowmeters are the solution for a wide variety of liquid and gas flow sensing applications. FT Series turbine flowmeters, which range in size from 3/8 inch to 24 inches, offer a high turn-down capability, repeatability of ±0.05% (liquid) and ±0.1% (gas) of reading, and excellent speed of response. The precision, axial-mounted rotor design of the standard turbine flowmeter allows it to operate effectively in flow rates from 0.03 to 50,000 GPM to (0.11 to 189,000 LPM) in liquid and 0.09 to 15,000 ACFM (2.55 to 424,800 ALPM) in gas, and pressures as high as 4,000 BAR (58,000 psi) for certain applications. Linearity is rated at ±0.5% of reading over the normal 10:1 turn-down range for liquid ( linearity of ±0.25% offered) and ±1.0% of full scale over the normal range for gas. All turbine flowmeters can achieve ±0.1% linearity with linearizing electronics. A choice of construction materials can be specified for the turbine flowmeter’s housing, rotor, bearings and shaft, including standard stainless steel, and exotic materials for specialized applications.
Applications Flow Technology offers a wide range of turbine flowmeters and custom-engineered designs for liquid and gas applications to meet the demands of the Aerospace, Industrial and Automotive s. Examples of applications include fuel consumption, hydraulics, coolant, gas injection, batching, ultra-pure water and of process variables in control systems.
Operation A volumetric device that measures the flow of both liquid and gases, the turbine flowmeter’s design is based on a freelysuspended turbine rotor which is rotated by the flow of fluid (liquid or gas) through the meter body.
FT Series Turbine Flowmeters
Features • High turndown capability, up to 100:1 • Excellent speed of response • Repeatability of ±0.05% (liquid) and ±0.1% (gas) of reading
• Linearity of ±0.5% of reading over normal 10:1 range for liquid, ±1% of full scale over the normal 10:1 range for gas
• Linearity of ±0.1% with linearizing electronics • Flow rates from 0.03 to 50,000 GPM (0.11 to 189,000 LPM) in liquid, 0.09 to 15,000 ACFM (2.55 to 424,800 ALPM) in gas
• Withstands pressures up to 400 BAR (5,800 psi), operation to 4,000 BAR (58,000 psi) optional
• Standard materials of construction are 316 SS housing and 430F SS rotor. Additional materials available
• End fittings available are NPT, AN (MS), Hose Barb, ANSI Flanges, SAE, Tri-clamp and special configurations as required
• High Shock meter designs available
FT Sizing BASED ON NORMAL RANGE
EXTENDED RANGE 5 DIGIT SERIES & SIZE
END FITTING NOMINAL INCHES
NORMAL FLOW RANGE 10:1
METER I.D. MM
INCHES
MIN
MAX
LIQUID
JOURNAL BEARINGS
NOMINAL K-FACTOR APPROX.
ALL
PICKOFFS
MIN
MAX
LPM
GPM
RF MIN
MAG MIN
RF MIN
MAG MIN
LPM
GPM
LPM
GPM
LPM
GPM
LPM
GPM
MAX. FREQ. APPROX.
ALL MAX LPM
GPM
P/L
P/G
Hz
FT 4-6
3/8
7.6
0.300
0.95
9.5 0.25
2.5
0.11
0.03
0.38
0.10
0.38
0.10
0.45
0.12
11
3 12680 48000
2000
FT 4-8
1/2
7.6
0.300
0.95
9.5 0.25
2.5
0.11
0.03
0.38
0.10
0.38
0.10
0.45
0.12
11
3 12680 48000
2000
FT 6-8
1/2
9.4
0.370
1.9
19
0.5
5.0
0.19
0.05
0.45
0.12
0.57
0.15
0.76
0.20
19
5
6600 25000
2100
FT 8-8
1/2
10
0.400
2.8
28 0.75
7.5
0.30
0.08
0.6
0.16
0.76
0.20
0.95
0.25
30
8
4200 16000
2000
FT-08
1/2
11
0.440
3.8
38
1.0
10.0
0.38
0.10
0.76
0.2
0.95
0.25
1.1
0.3
38
10
3170 12000
2000
FT-10
*5/8, 3/4
13
0.500
4.7
47 1.25
12.5
0.57
0.15
1.1
0.3
1.1
0.3
1.5
0.4
56
15
2540
9600
2000
FT-12
3/4
14
0.560
7.6
76
2.0
20
0.95
0.25
1.8
0.5
1.9
0.5
1.9
0.5
94
25
1580
6000
2000
FT-16
1
22
0.860
19
190
5.0
50
2.3
0.6
3.7
1.0
3.8
1.0
3.8
1.0
227
60
635
2400
2000
FT-20
1 1/4
25
1.00
34
340
9.0
90
3.8
1.0
5.6
1.5
3.8
1.0
5.7
1.5
378
100
345
1300
1950
FT-24
1 1/2
34
1.32
57
570
15
150
6.0
1.6
9.4
2.5
6.0
1.6
9.5
2.5
605
160
160
600
1500
FT-32
2
44
1.75
85
850
22
225
9.5
2.5
13
3.5
9.5
2.5
13
3.5
946
250
92
350
1300
FT-40
2 1/2
56
2.22
151
1510
40
400
17.0
4.5
19
5.0
17
4.5
19
5.0
1700
450
48
180
1200
FT-48
3
73
2.87
246
2460
65
650
N/A
28
7.5
N/A
28
7.5
2838
750
20
75
812
FT-64
4
98
3.87
473
4730
125
1250
N/A
57
15
N/A
57
15
5677 1500
8
30
625
FT-96
6
152
6.00
1135
11350
300
3000
N/A
190
50
N/A
190
50
13246 3500
7.5
28
1400
FT128
8
203
8.00
2082
20820
550
5500
N/A
227
60
N/A
227
60
22710 6000
3.7
14
1300
FT160
10
254
10.00
3217
32170
850
8500
N/A
378
100
N/A
378
100
37848 10000
2.2
8.5
1200
FT192
12
305
12.00
4542
45420 1200 12000
N/A
568
150
N/A
568
150
56772 15000
1.3
5.0
1000
ALPM
ACFM
FT 2-8
1/2
9.4
**0.370
2.83
FT 4-8
1/2
7.6
**0.300
7.0
FT 6-8
1/2
9.4
**0.370
14.0
140
FT 8-8
1/2
10
**0.400
FT-08
1/2
11
**0.440
FT-10
*5/8, 3/4
13
FT-12
3/4
14
FT-16
1
22
FT-20
1 1/4
25
1.00
255
2550
9
FT-24
1 1/2
34
1.32
425
4250
15
FT-32
2
44
1.75
623
6230
22
FT-40
2 1/2
56
2.22
1133
11330
FT-48
3
73
2.87
1841
FT-64
4
98
3.87
FT-96
6
152
6.00
FT128
8
FT160 FT192
ALPM
GAS
BALL BEARINGS
ALPM
ACFM
28.3
ACFM
ALPM
ACFM
1.0
2.55
0.09
N/A
N/A
N/A
35.5
1.25
3284 93000
70 0.25
2.5
5.7
0.2
N/A
N/A
N/A
85
3.0
1589 45000
2000
0.5
5.0
7.1
0.25
11.4
N/A
N/A
141.6
5.0
848 24000
2000
21.2
212 0.75
7.5
11.5
0.4
14.2
0.5
N/A
N/A
226.5
8.0
565 16000
2000
28.3
283
1.0
10
14.5
0.5
21.3
0.75
N/A
N/A
283
10
424 12000
2000
0.500
35.4
354 1.25
12.5
17
0.6
28.4
1.0
N/A
N/A
424
15
339
9600
2000
0.560
56.6
566
2
20
28.5
1.0
42.5
1.5
N/A
N/A
708
25
212
6000
2000
0.860 141.6
1416
5
50
42.5
1.5
71
2.5
N/A
N/A
1699
60
85
2400
2000
90
71
2.5
142
5
N/A
N/A
2832
100
46
1300
1950
150
114
4
170
6
N/A
N/A
4531
160
21
600
1500
220
142
5
228
8
N/A
N/A
7080
250
12
350
1300
40
400
255
9
284
10
N/A
N/A
12744
450
6.3
180
1200
18410
65
650
N/A
425
15
N/A
N/A
21240
750
3
75
812
3540
35400
125
1250
N/A
850
30
N/A
N/A
42480 1500
1
30
625
8496
84960
300
3000
N/A
1983
70
N/A
N/A
99120 3500
0.31
9.0
467
203
8.00 15576 155760
550
5500
N/A
3399
120
N/A
N/A
169920 6000
0.14
4.0
325
10
254
10.00 24072 240720
850
8500
N/A
5664
200
N/A
N/A
283200 10000
0.07
2.0
240
12
305
12.00 33984 339840 1200 12000
N/A
8496
300
N/A
N/A
424800 15000
0.035
1.0
167
Hose Barb
1550
*AN = 5/8" All Others = 3/4"
Blue = Metric (SI) Units
Black = English (US) Units
**0.440 bore when used with “H” bearing code
Metric units in LPM (liquid) & ALPM (gas)
English units in GPM (liquid) & ACFM (gas)
F
Tri-Clamp
P/Ft3
P/L
0.1
0.4
AN (MS)
Grayloc
T Series & Size
End Fittings
Abbreviations for Units of Measure: LPM = Liters per Minute GPM = Gallons per Minute
ALPM = Actual Liters per Minute ACFM = Actual Cubic Feet per Minute
P/L = Pulses per Liter P/G = Pulses per Gallon P/Ft 3 = Pulses per Cubic Foot
Calib
Model Numbering System Calibration End Fittings
AN (MS)
Tri-Clamp
NPT/BSP
ANSI/DIN Raised Face Flange
Hose Barb ANSI Ring t Flange
Grayloc
on bic Foot
AE = AN (or MS) external straight threads, 3/8" to 2 1/2" nominal size, 37° flare NE = NPT external threads, 1/2" to 4" nominal size HB = Hose Barb, 13 to 51 mm/ 1/2" to 2" BE = British Standard tapered pipe thread per BS21:1973, 1/2" to 4" BS = British Standard straight thread Thread per ISO 228-1, Sealing surface per DIN 3852, part 2, type A, 1/2" to 2" WF = Wafer type, serrated surface, 13 to 76 mm/1/2" to 3" nominal size C1 = 150# Raised Face Flange C2 = 300# Raised Face Flange C3 = 600# Raised Face Flange C4 = 900# Raised Face Flange C5 = 1500# Raised Face Flange C6 = 2500# Raised Face Flange J1 = 150# Ring t Flange J2 = 300# Ring t Flange J3 = 600# Ring t Flange J4 = 900# Ring t Flange J5 = 1500# Ring t Flange J6 = 2500# Ring t Flange G1 = 1/2", 1GR4 Grayloc, 900 BAR G2 = 3/4", 1GR7 Grayloc, 460 BAR G3 = 1", 1GR11 Grayloc, 227 BAR G5 = 1 1/2", 11/2GR14 Grayloc, 390 BAR G6 = 1 1/2", 2GR14 Grayloc, 600 BAR G7 = 2", 3GR25 Grayloc, 435 BAR G8 = 3", 3GR27 Grayloc, 225 BAR G9 = 3", 4GR25 Grayloc, 675 BAR
CODE Note:
DESCRIPTION A=Air, W=Water, S=Solvent, B=Oil Blend Viscosity must be provided with oil blend calibrations “B”
CODE
DESCRI
U2
NA NW NS NB
10 10 10 10
point, point, point, point,
normal normal normal normal
U3
Universa (specify m viscosity Universa (specify m viscosity
XA XW XS XB
10 10 10 10
point, point, point, point,
extended extended extended extended
TA TW TS TB
20 20 20 20
point, point, point, point,
normal normal normal normal
YA YW YS YB
20 20 20 20
point, point, point, point,
extended extended extended extended
range, range, range, range,
in in in in
air water solvent oil blend
FA FW FS FB
15 15 15 15
point, point, point, point,
extended extended extended extended
range, range, range, range,
in in in in
air water solvent oil blend
GA GW GS GB
30 30 30 30
point, point, point, point,
extended extended extended extended
range, range, range, range,
in in in in
air water solvent oil blend
10:1 10:1 10:1 10:1
range, range, range, range,
in in in in
air water solvent oil blend
BA range, range, range, range,
10:1 10:1 10:1 10:1
in in in in
range, range, range, range,
air water solvent oil blend in in in in
BW BS BB
air water solvent oil blend
CA CW CS CB
LW LS
Calibration
– = Standard R = Range U = Units B = Both
R1 R2 R3
10 points 10 points 10 points
E1 E2 E3
20 points 20 points 20 points
The third digit of the calibration designator is normally not used and occupied by a dash (–). When required, the following codes are used: U — To signify required units of measure other than GPM or ACFM R — To signify special calibration flow range other than normal 10:1 or extended range B — To signify both changes in units and special flow range
L = Liquid G = Gas P = Gas with Pressure Tap
Bi-direct sensing, Bi-direct sensing, Bi-direct sensing, Bi-direct sensing,
Specify Temp. &
Note: Additional Grayloc fittings available. Please factory with pressure and size specifications.
T1 = Tri-Clamp 1/2" to 3/4" T2 = Tri-Clamp 1" to 1 1/2" T3 = Tri-Clamp 2" T4 = Tri-Clamp 3" D1 = DIN Flange PN16 D2 = DIN Flange PN40 D3 = DIN Flange PN100 D4 = DIN Flange PN160 D5 = DIN Flange PN250 D6 = DIN Flange PN400
Bi-direct direction Bi-direct direction Bi-direct direction Bi-direct direction
Material
Materials of Construction MATERIAL CODE 1 D E G H N Q R T
PTION
al Viscosity Curve, 2 Viscosities minimum viscosity & maximum y). 10 points each viscosity al Viscosity Curve, 3 Viscosities minimum viscosity & maximum y). 10 points each viscosity
ional, 1 pickoff, , air ional, 1 pickoff, , water ional, 1 pickoff, , solvent ional, 1 pickoff, , oil blend
10 points each
ROTOR 17-4 PH SST 430F SST 316 SST 17-4 PH SST HAST C PVC MONEL-400 CARP 20 2
(Bearings offered with material code. See bearings below.)
A, D, G A, D, E, G, H D, E, G A, D, E, G, H E, G E, G D, E, G E, G
Material code “D” is for standard 6"/152 mm or larger. Rotor material other than 430F SST or 17-4 PH SST will require special handling in the form of a ferrous slugged rotor or special processing electronics. Please the factory for any further information.
1
10 points each
2
10 points each 10 points each
Bearings
ional, 2 pickoffs, direction 10 points each direction, air ional, 2 pickoffs, direction 10 points each direction, water ional, 2 pickoffs, direction 10 points each direction, solvent ional, 2 pickoffs, direction 10 points each direction, oil blend
Bearing selection will affect Flow Range. Refer to sizing specification table for correct Flow Ranges. A D E G H
m linearity, 10 point, 10:1 range, water m linearity, 10 point, 10:1 range, solvent Press., Min/Max, for Reynolds No. Cal.
s, 1 pressure, Reynolds No. Cal. s, 2 pressure, Reynolds No. Cal. s, 3 pressure, Reynolds No. Cal.
— — — — —
Ball Bearings (440 C) Carbide Journal (Carbide Shaft & Sleeve) liquid only Graphite Journal (Graphite Sleeve, 316 SST Shaft) liquid only Ceramic Journal (Ceramic Shaft & Sleeve) liquid only Ball Bearing (440 C Teflon Retainer) gas only (Offered on FT-64 and smaller)
Pickoffs The following is a listing of some of the pickoffs that are available from Flow Technology. –1 = Modulated Carrier, MS connector –2 = Magnetic, MS connector –3 = Magnetic, flying leads/threaded connection –5 = Modulated Carrier, flying leads/threaded connection –6 = Magnetic, MS connector, 400° C/750° F max –7 = Magnetic, flying leads/threaded connection 400° C/750° F max –L = Modulated Carrier, MS connector, 400° C/750° F max –M = Modulated Carrier, flying leads/threaded connection 400° C/750° F max –8 = Modulated Carrier, MS connector, 330 µH coil –9 = Modulated Carrier, MS connector, 5/8"–18 thread, 1mH coil –Y = Modulated Carrier, CSA X-Proof –Z = Magnetic, CSA X-Proof T1 = Modulated Carrier w/RTD, MS connector T2 = Magnetic w/RTD, MS connector T3 = Magnetic w/RTD, flying leads/threaded connection T5 = Modulated Carrier w/RTD, flying leads/threaded connection –X = Modulated Carrier, I.S. approved, MS connector SS = Modulated Carrier, I.S. approved, flying leads/smooth body XX = Modulated Carrier, I.S. approved, flying leads/threaded body –U = Magnetic, I.S. approved, MS connector PP = Magnetic, I.S. approved, flying leads/smooth body TT = Magnetic, I.S. approved, flying leads/threaded body Note: 1. Maximum temperature rating of pickoffs are 177° C (350° F) unless otherwise noted. 2. See Amplifier Link literature for amplified pickoff codes.
s, 1 pressure, Reynolds No. Cal. s, 2 pressure, Reynolds No. Cal. s, 3 pressure, Reynolds No. Cal.
Bearing
BEARING CODE HOUSING 304 SST 316 SST 316 SST 316 SST HAST C PVC MONEL-400 CARP 20
Pickoff
Optional Designators (Consult Factory)
Please note: Highlighted areas indicate standard base price configuration.
Dime
Operation (cont’d) An external pickoff senses the ing of each rotor blade, generating a frequency output. The frequency is directly proportional to the velocity of the fluid, and since the flow age is fixed, the turbine’s rotational speed is a true representation of the volumetric rate of fluid flowing through the flowmeter.
Specifications Applicable to Both Liquid and Gas Flowmeters Materials Of Construction Standard
316 SST Housing 430F SST Rotor 440 C Ball Bearings Stainless steel all other wetted parts
Other materials of construction optional (see model number chart). Operating Temp. Range
Defined by pickoff and bearing selection
Bearing Type Temperature Limits: 440 C stainless steel -450° F to 300° F ball bearings (-270° C to 150° C) Note: Not recommended for water service. Ceramic journal bearings
-100° F to 800° F (-75° C to 425° C)
Graphite journal bearings
-100° F to 550° F (-75° C to 290° C)
Tungsten carbide -100° F to 1,200° F journal bearings (-75° C to 650° C) Note: Journal bearings are for liquid service only.
Either a Magnetic or Modulated Carrier (RF) pickoff with a range extending amplifier can be used to sense the rotation of the turbine rotor and provide an electrical output that is proportional to the process flow rate. A benefit of the RF pickoff is that it extends the low flow range of the meter by eliminating magnetic drag on the rotor. The frequency output is processed by complementary electronics, ranging from basic amplifiers, indicators and totalizers, to more complex flow computers which compensate for all measurable process parameters and provide ultimate volumetric or mass flow measurement accuracy.
Series
mm FT-_8 FT-10 FT-12 FT-16 FT-20 FT-24 FT-32 FT-40 FT-48 FT-64 FT-96 FT128 FT160 FT192
127 140 140 140 152 152 165 178 254 305 356 406 508 610
Liquid Service Liquid service performance specifications are based on a viscosity of 1.2 centistokes using ball bearings. Calibration Accuracy
≤±0.05% of reading (accuracy of primary flow calibration standard directly traceable to NIST)
Repeatability
≤±0.05% of reading
Linearity
≤±0.5% of reading over the normal 10:1 flow range ( linearity of ±0.25% offered)
Series
A
mm FT-–8 FT-10 FT-12 FT-16 FT-20 FT-24 FT-32 FT-40 FT-48 FT-64 FT-96
48 49 49 64 64 64 76 133 146 127 155
±0.1% of reading with linearizing electronics Pressure Drop
Less than 700 mBAR (10 psid) at maximum 10:1 flow rate
Series
D
Temperature Limits: -430° F to 350° F (-260° C to 177° C) 10 mV min.
Dynamic Response
Less than 10 mS response to a step input change of flow rate
-430° F to 750° F (-260° C to 400° C) 10 mV min.
Gas Service
Modulated Carrier (RF)
-300° F to 350° F (-185° C to 177° C)
Gas service performance specifications are based on air at standard conditions 1 BAR and 20° C (14.7 psia and 68° F) with ball bearings.
High Temp. (RF)
Up to 750° F (400° C)
FT-–8 FT-10 FT-12 FT-16 FT-20 FT-24 FT-32 FT-40 FT-48 FT-64 FT-96 FT128 FT160 FT192
1 2 2 2 3 4 5 6 8 10 15 20 25 30
Pickoff Type Magnetic Output: High Temp. Magnetic Output:
Pickoff Electronic Connections MS Connector 2-pin, standard pickoff 15-89515-101 3-pin, amplified pickoff 15-89515-102 4-pin, pickoff with RTD 15-93825-01 Threaded Connection with Leads Junction Box with Terminal 73-31836-105 Operating Pressure Range
Defined by end connection rating up to 400 BAR (5,800 psi) standard. Special high pressure available up to 4,000 BAR (58,000 psi)
Filtration Recommendations Ball Bearings 10 micron to 100 micron (with less filtration for large sizes) Journal Bearings
100 micron
Calibration Accuracy
≤±0.3% of reading (accuracy of primary flow calibration standard directly traceable to NIST)
Repeatability
≤±0.1% of reading
Linearity
≤±1.0% of full scale over the normal 10:1 flow range ±0.1% of reading with linearizing electronics
Note: 1) 2) 3) 4)
Con All A NPT Waf
Specifications a
Pressure Drop
Pressure Tap
Less than 40 mBAR (16 inches of water) at normal 10:1 maximum flow rate Optional on all gas meters 7/16-2OUNJF-3A thread, MS33656, for flared 1/4" O.D. tube, AN806-4
Local R
Dimensions A
Series FT-_8 FT-10 FT-12 FT-16 FT-20 FT-24 FT-32 FT-40 FT-48 FT-64 FT-96 FT128 FT160 FT192
B
PICKOFF
A
150#
300#
mm
in.
mm
in.
mm
in.
mm
in.
mm
in.
5.0 5.5 5.5 5.5 6.0 6.0 6.5 7.0 10.0 12.0 14.0 16.0 20.0 24.0
89 99 99 108 118 127 152 178 191 229 279 343 406 483
3.5 3.88 3.88 4.25 4.63 5.0 6.0 7.0 7.5 9.0 11.0 13.5 16.0 19.0
127 140 140 140 152 152 165 178 254 305 356 406 508 610
5.0 5.5 5.5 5.5 6.0 6.0 6.5 7.0 10.0 12.0 14.0 16.0 20.0 24.0
95 118 118 124 133 156 165 191 210 254 318 381 445 521
3.75 4.63 4.63 4.88 5.25 6.13 6.5 7.5 8.25 10.0 12.5 15.0 17.5 20.5
127 140 140 140 152 152 165 229 254 305 356 406 508 610
5.0 5.5 5.5 5.5 6.0 6.0 6.5 9.0 10.0 12.0 14.0 16.0 20.0 24.0
FT-10 FT-12 FT-16 FT-20 FT-24 FT-32 FT-40 FT-48 FT-64 FT-96
Series
48 49 49 64 64 64 76 133 146 127 155
DN
B
A
in.
mm
in.
1.88 1.90 1.90 2.50 2.50 2.50 3.00 5.25 5.75 5.00 6.12
35 43 43 51 64 73 92 105 127 157 216
1.38 1.70 1.70 2.00 2.50 2.88 3.62 4.12 5.00 6.18 8.50
PN 16 A B mm
FT-–8 FT-10 FT-12 FT-16 FT-20 FT-24 FT-32 FT-40 FT-48 FT-64 FT-96 FT128 FT160 FT192
15 20 20 25 32 40 50 65 80 100 150 200 250 300
127 140 140 140 152 152 165 178 254 305 356 406 508 610
A
95 105 105 115 140 150 165 185 200 220 285 340 405 460
mm 62 69 83 90 103 117 154 164 244
B
mm
in.
mm
in.
mm
in.
95 3.75 118 4.63 118 4.63 124 4.88 133 5.25 156 6.13 165 6.5 191 7.5 210 8.25 273 10.75 356 14.0 419 16.5 508 20.0 559 22.0
178 140 178 203 203 229 229 229 254 305 356 406 508 610
7.0 5.5 7.0 8.0 8.0 9.0 9.0 9.0 10.0 12.0 14.0 16.0 20.0 24.0
121 130 130 149 159 178 216 241 241 292 381 470 546 610
4.75 5.13 5.13 5.88 6.25 7.0 8.5 9.5 9.5 11.5 15.0 18.5 21.5 24.0
B
J
M
in.
mm
in.
mm
in.
mm
in.
2.45 2.72 3.25 3.56 4.06 4.59 6.06 6.47 9.59
25 35 35 41 48 57 70 73 89
1.00 1.38 1.38 1.63 1.88 2.25 2.75 2.88 3.50
62.20 69.10 82.60 90.40 103.10 116.60 153.90 157.23 244.00
2.45 2.72 3.25 3.56 4.06 4.59 6.06 6.19 9.59
12.70 15.50 19.10 25.40 31.80 38.10 50.80 64.00 76.00
0.50 0.61 0.75 1.00 1.25 1.50 2.00 2.50 3.00
14.70 17.80 21.10 28.50 34.80 41.70 54.90 68.00 81.00
0.58 0.70 0.83 1.12 1.37 1.64 2.16 2.67 3.17
178 140 140 140 152 152 165 178 254 305 356 406 508 610
105 105 140 140 155 170 195 220 230 265 355 430 515 585
Composite drawing showing MS end connections on the upper portion of the flowmeter and NPT/BSP threads on the lower portion. Pickoff is a 2-pin MS connector.
PN 250 A B
PN 400 A B
mm
mm
mm 178 140 178 203 203 229 229 254 254 305 356 406 508 610
Hose Barb flowmeter with 2-pin MS connector pickoff.
2.0" MAX (50.8mm)
DIN FLANGED PN 40 PN 100 PN 160 A B A B A B 95 105 105 115 140 150 165 185 200 235 300 375 450 515
NPT A END-TO-END
PICKOFF
CONSULT FACTORY
127 140 140 140 152 152 165 178 254 305 356 406 508 610
FLOW
N
mm
mm
B FLATS
HOSE BARB
in.
mm
2.0" MAX (50.8mm)
THREADS PER MS33656
900#
AN OR MS NPT OR BSP EXTERNAL THREADS
A mm
FT-–8
B 600#
127 140 140 140 152 152 165 178 254 305 356 406 508 610
WAFER
Series
ANSI FLANGED B A
105 140 140 140 170 170 195 220 230 265 355 430 515 585
178 140 178 203 203 229 229 254 254 305 356 406 508 610
130 150 150 150 185 185 200 230 255 300 390 485 585 690
178 140 178 203 203 229 229 254 254 311 356 406 -
B DIA FLOW
145 180 180 180 220 220 235 290 305 370 475 585 -
0.02" (0.5mm) FACE-TO-FACE A±
FT Series flowmeter with wafer end connections. Pickoff with flying leads and a 1" NPT enclosure connection on FT-16 and larger.
DIN/ANSI RAISED FACE, FLAT FACE OR RING T FLANGE
PICKOFF
2.0" MAX (50.8mm) B DIA
Blue = Metric (SI) Units mm = millimeters Note: 1) 2) 3) 4)
Black = English (US) Units in. = inches
Consult factory for Grayloc end fitting dimensions. All ANSI flanged meters will have a 1" NPT spud around pickoff. NPT meters 2 1/2" and larger will have a 1" NPT spud around pickoff. Wafer meters 1" and larger will have a 1" NPT spud around pickoff.
Specifications and dimensions are for reference only and are subject to change without notice.
FLOW
0.06" (1.5mm) FACE-TO-FACE A±
FT Series flowmeter with flanged end connections. Pickoff with flying leads and a 1" NPT spud enclosure connection.
Local Representative:
4250 E. Broadway Road, Phoenix, Arizona 85040 USA Tel: (602) 437-1315 • Fax: (602) 437-4459 • Toll Free: 1-800-528-4225 E-mail:
[email protected] • Web: www.ftimeters.com DB 62042 Rev G © 2002 FTI Flow Technology, Inc. Printed in USA